Pre-wired Type | Connector Type | Pre-wired Connector Type |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
Connector Type |
Different Frequency Type |
Robotics Cable Type |
||||||||
NPN etc. | PNP | |||||||||||
E2E | DC 2-Wire |
Shielded |
M8 | 2 | • Short type • Oil resistant • Enhanced fastening strength • Equipped with cable protector |
DC (2-Wire) |
NO or NC |
- | ○ -Partially |
- | ○ -Partially |
E2E-X2D□-□ |
M12 | 3 | ○ -Partially |
E2E-X3D□-□ | |||||||||
M18 | 7 | E2E-X7D□-□ | ||||||||||
M30 | 10 | E2E-X10D□-□ | ||||||||||
Unshielded |
M8 | 4 | - | E2E-X4MD□-□ | ||||||||
M12 | 8 | ○ -Partially |
E2E-X8MD□-□ | |||||||||
M18 | 14 | E2E-X14MD□-□ | ||||||||||
M30 | 20 | E2E-X20MD□-□ | ||||||||||
DC 3-Wire, AC 2-Wire |
Shielded |
M8 | 1.5 | • Oil resistant • Equipped with cable protector • Enhanced fastening strength |
DC (3-Wire) or AC |
DC Type : NPN NO or NC AC Type : NO or NC |
PNP NO or NC |
○ -Partially |
- | ○ -Partially |
E2E-X1R5□-□ | |
M12 | 2 | ○ -Partially |
E2E-X2□-□ | |||||||||
M18 | 5 | E2E-X5□-□ | ||||||||||
M30 | 10 | E2E-X10□-□ | ||||||||||
Unshielded |
M8 | 2 | - | E2E-X2M□-□ | ||||||||
M12 | 5 | ○ -Partially |
E2E-X5M□-□ | |||||||||
M18 | 10 | E2E-X10M□-□ | ||||||||||
M30 | 18 | E2E-X18M□-□ | ||||||||||
DC 3-Wire |
Shielded |
3dia. | 0.6 | • Small diameter | DC (3-Wire) |
NPN NO or NC |
PNP NO or NC |
- | - | ○ -Partially |
E2E-CR6□□ | |
4dia. | 0.8 | E2E-CR8□□ | ||||||||||
M5 | 1 | E2E-X1□□ | ||||||||||
5.4dia. | 1 | E2E-C1□□ | ||||||||||
DC/AC 2-Wire |
Shielded |
M12 | 3 | • Ideal for maintenance | DC AC Selectable (2-Wire) |
NO | - | - | - | - | E2E-X3T1 | |
M18 | 7 | E2E-X7T1 | ||||||||||
M30 | 10 | E2E-X10T1 | ||||||||||
E2EM | DC 2-Wire |
Shielded |
M12 | 4 | • Long distance • Short type • Oil resistant • Enhanced fastening strength • Equipped with cable protector |
DC (2-Wire) |
NO or NC |
- | ○ -Partially |
- | - | E2EM-X4X□-□ |
M18 | 8 | E2EM-X8X□-□ | ||||||||||
M30 | 15 | E2EM-X15X□-□ | ||||||||||
Unshielded |
M18 | 16 | E2EM-X16MX□-□ | |||||||||
M30 | 30 | E2EM-X30MX□-□ | ||||||||||
DC 3-Wire |
Shielded |
M8 | 2 | • Long distance • Oil resistant • Equipped with cable protector • Enhanced fastening strength |
DC (3-Wire) |
DC Type : NPN NO or NC |
- | ○ -Partially |
- | - | E2EM-X2C□-□ | |
M12 | 4 | E2EM-X4C□-□ | ||||||||||
M18 | 8 | E2EM-X8C□-□ | ||||||||||
M30 | 15 | E2EM-X15C□-□ |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions
before using.
* Robotics cables are not provided on standard products but can be ordered by adding “-R” to the standard product model numbers.
Pre-wired Type | Connector Type | Pre-wired Connector Type |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |
---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
|||||||
E2EQ | Long Distance Anti-Spatter |
Shielded |
M12 | 4 | • Long distance type • Pre-wired connector type • Metal case with Fluororesin coating |
DC (2-Wire) |
NPN NO |
E2EQ-X4X1-□ |
M18 | 8 | E2EQ-X8X1-□ | ||||||
M30 | 15 | E2EQ-X15X1-□ | ||||||
Anti-Spatter |
Shielded |
M12 | 3 | • Standard type • Pre-wired connector type • Metal case with Fluororesin coating |
DC (2-Wire) |
NPN NO |
E2EQ-X3D1-□ | |
M18 | 7 | E2EQ-X7D1-□ | ||||||
M30 | 10 | E2EQ-X10D1-□ | ||||||
E2FM | All Stainless Steel Metal Head |
Shielded |
M8 | 1.5 | • Full Stainless Steel Body • Enhanced strength and wear resistance of sensor surface |
DC (2-Wire or 3-Wire) |
NO | E2FM-X1R5□-□ |
M12 | 2 | E2FM-X2□-□ | ||||||
M18 | 5 | E2FM-X5□-□ | ||||||
M30 | 10 | E2FM-X10□-□ | ||||||
E2EH | LHigh-Temperature, Washable Type |
Shielded |
M12 | 3 | • SUS316L Body • High temperature: 100°C (120°C/1000 hrs) • IP69K • Detergent resistant |
DC (2-Wire or 3-Wire) |
NO or NC NPN/PNP or DC 2-Wire |
E2EH-X3D□ |
M18 | 7 | E2EH-X7D□ | ||||||
M30 | 12 | E2EH-X12D□ | ||||||
E2FQ | Chemical Resistant Type |
Shielded |
M12 | 2 | • Fluororesin case | DC (2-Wire or 3-Wire) AC |
DC 3-Wire : NPN NO DC 2-Wire and AC Types : NO |
E2FQ-X2□ |
M18 | 5 | E2FQ-X5□ | ||||||
M30 | 10 | E2FQ-X10□ | ||||||
E2EZ | Anti-Aluminum Chip Type |
Shielded |
M12 | 2 | • Pre-wired connector type available • Setting operation indicator (DC 2-Wire) |
DC (2-Wire or 3-Wire) AC |
DC 3-Wire : NPN NO DC 2-Wire : NO or NC AC Type : NO |
E2EZ-X2D□-□ |
M18 | 4 | E2EZ-X4□-□ | ||||||
M30 | 8 | E2EZ-X8□-□ |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Pre-wired Type |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
Connector Type |
Different Frequency Type |
Robotics Cable Type |
||||||||
NPN etc. | PNP | |||||||||||
E2F | Resin Case Type |
Shielded |
M8 | 1.5 | • IEC standard-IP68 compliant protective structure |
DC (3-Wire) or AC |
DC Type : NPN NO or NC AC Type : NO or NC |
- | - | - | - | E2F-X1R5□ |
M12 | 2 | ○ | E2F-X2□ | |||||||||
M18 | 5 | E2F-X5□ | ||||||||||
M30 | 10 | E2F-X10□ |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |
---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
|||||||
E2V |
All-metal and Pre-wired/ |
Shielded |
M12 | 4 | • Long-distance Sensor that is shielded • Aluminum chip immunity function • Operation indicator is visible at any direction |
DC (3-Wire) |
NPN/PNP NO or NC |
E2V-X4□ |
M18 | 8 | E2V-X8□ | ||||||
M30 | 15 | E2V-X15□ | ||||||
E2EY | For Aluminum Detection |
Shielded |
M18 | 4 | • Detects non-ferrous metals such as aluminum and brass • Iron and nickel not detected |
DC (3-Wire) |
DC 3-Wire : NPN NO |
E2EY-X4C1 |
M30 | 8 | E2EY-X8C1 | ||||||
E2EV | All-metal |
Shielded |
M12 | 2 | • Able to detect different kinds of metals • Detecting distance is three times longer for aluminum • Long distance detection of non-iron metals |
DC (3-Wire) |
NPN NO or NC |
E2EV-X2C□ |
M18 | 5 | E2EV-X5C□ | ||||||
M30 | 10 | E2EV-X10C□ |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
Connector Type |
Different Frequency Type |
Robotics Cable Type |
||||||||
NPN etc. | PNP | |||||||||||
E2S | Miniature Size, Square, DC 2-Wire W×L×D |
Unshielded |
5.5×19×5.5 | 1.6 | • Miniature size • Long distance • Top and front surface detection • Low current consumption |
DC (2-Wire) |
NO or NC |
- | - | - | - | E2S-W1□ |
E2S-Q1□ | ||||||||||||
8×20×8 | 2.5 | E2S-W2□ | ||||||||||
E2S-Q2□ | ||||||||||||
DC 3-Wire W×L×D |
5.5×19×5.5 | 1.6 | DC (3-Wire) |
NO or NC |
○ | E2S-W□□ | ||||||
8×20×8 | 2.5 | E2S-Q□□ | ||||||||||
TL-W | Flat Type W×L×D |
Shielded |
24.9×50×10 | 5 | • Top surface detection • DC 2-Wire type available for 5mm type (unshielded) |
DC (3-Wire), Partially (2-Wire) |
NPN NO or NC |
PNP NO or NC |
- | - | - | TL-W5□□ |
8×25×5.5 | 1.5 | 3-Wire : NPN NO or NC 2-Wire : NO or NC |
- | ○ | ○ -Partially |
TL-W1R5MC1 | ||||||
10×27×6 | 3 | TL-W3MC□ | ||||||||||
Unshielded |
18×30.5×10 | 5 | TL-W5M□ | |||||||||
40×53×23 | 20 | - | TL-W20ME□ | |||||||||
TL-W | W×L×D |
Unshielded |
25×38.5 | 7 | • Long distance detection • DC 2-Wire |
DC (2-Wire) |
NO or NC |
- | - | ○ | - | TL-N7MD□ |
30×52.5 | 12 | TL-N12MD□ | ||||||||||
40×53 | 20 | TL-N20MD□ | ||||||||||
25×38.5 | 5 | • DC 3-Wire • AC 2-Wire |
DC (3-Wire) |
DC Type : NPN NO or NC AC Type : NO or NC |
- | ○ | TL-N5ME□ | |||||
25×50 | AC | - | TL-N5MY□ | |||||||||
30×52.5 | 10 | DC (3-Wire) |
○ -Partially |
TL-N10ME□ | ||||||||
AC | TL-N10MY□ | |||||||||||
40×53 | 20 | DC (3-Wire) |
○ -Partially |
TL-N20ME□ | ||||||||
AC | TL-N20MY□ |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions
before using.
* Robotics cables are not provided on standard products but can be ordered by adding “-R” to the standard product model numbers.
Series | Sensor Unit | ||||||
---|---|---|---|---|---|---|---|
Appearance | Type | Size | Detecting Distance (Unit:mm) |
Repeat- ability |
Model | ||
E2C-EDA | Shielded | Cylindrical | 3dia.× 18mm |
0.6 | 1μm | E2C-EDR6-F (*2) |
5.4dia.× 18mm |
1 | 1μm | E2C-ED01-□ (*1*2*3) |
8dia.× 22mm |
2 | 2μm | E2C-ED02-□ (*1*2*3) |
Screw | M10× 22mm |
2 | 2μm | E2C-EM02-□ (*1*2*3) |
Flat | 30×14× 4.8mm |
5 | 2μm | E2C-EV05-□ (*1*2*3) |
Unshielded | Screw | M18× 46.3mm |
7 | 5μm | E2C-EM07M-□ (*1*2*3) |
Heat-resistant | Screw | M12× 22mm |
2 | 2μm | E2C-EM02H (*2) |
Amplifier Unit | |||||
---|---|---|---|---|---|
Appearance | Classification | Power Supply |
Output Configuration |
||
NPN Outbut |
PNP Output |
||||
Pre-wired Type |
Advanced Type |
Twin Output |
DC | E2C -EDA11 |
E2C -EDA41 |
External Output |
E2C -EDA21 |
E2C -EDA51 |
Connector Type |
Advanced Type |
Twin Output |
E2C -EDA6 |
E2C -EDA8 |
External Output |
E2C -EDA7 |
E2C -EDA9 |
*1 A protective spiral tube is supplied. This is indicated by “-S” at the end of the model number. (Example: E2C-ED01-S)
*2 Two types of cable length are available. (3dia. is a free-cut cable. Heat-resistant type comes only with the standard cable length.)
     Total length of standard length type: 2.5m / Distance between head and preamplifier: 2m (Example: E2C-ED01)
     Total length of free-cut type: 3.5m / Distance between head and preamplifier: 0.5m. This is indicated by “-F” at the end of the model number. (Example: E2C-ED01-F)
*3 Models with protective spiral tube (indicated by “-S”) and free-cut cable type (indicated by “-F”) are available on a custom-made basis.
Series | Sensor Unit | Model | ||||
---|---|---|---|---|---|---|
Appearance | Shielded/ Unshielded |
Size | Stable Detection Range (Unit : mm) |
Maximum Operating Distance |
||
E2C | |
Shielded |
3.5dia. | 0.8 | 1.8 | E2C-CR8A | 3.8dia. | E2C-CR8B | M5 | 1 | 2 | E2C-X1A | 5.4dia. | E2C-C1A | M8 | 1.5 | 3 | E2C-X1R5A | M12 | 2 | 5 | E2C-X2A | M18 | 5 | 10 | E2C-X5A | M30 | 10 | 18 | E2C-X10A | Unshielded | 40dia. | 20 | 50 | E2C-C20MA |
Amplifier Unit | ||
---|---|---|
Model | Power Supply | Features |
E2C-GE4B | DC | Miniature Size |
E2C-GF4B | E2C-GE4A | |
E2C-GF4A | E2C-WH4A | Slim DIN Rail Mount | E2C-WH4AF | E2C-JC4AP | Slim Off-Delay Timer Feature | E2C-JC4A | E2C-AM4A | Adjustable Hysteresis | E2C-AK4A | AC | Adjustable Hysteresis Solid-state Relay Output |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Pre-wired Type |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
Connector Type |
Different Frequency Type |
Robotics Cable Type |
||||||||
NPN etc. | PNP | |||||||||||
E2EC-M E2EC-Q |
Amplifier Relay Type |
Shielded |
8dia. | 2 | • Stainless Steel Head • Robotic Cable • Fluororesin Coating(-Q) |
DC (2-Wire or 3-Wire) |
NO | NO | ○ | - | ○ | E2EC-MC2D1 |
E2EC-MC2B1 | ||||||||||||
E2EC-QC2D1-M1GJ-T | ||||||||||||
E2EC | Amplifier Relay Type |
Shielded |
3dia. | 0.8 | • Equipped with robotic cable | DC (2-Wire) |
NO or |
- | - | ○ | ○ | E2EC-CR8D□ |
5.4dia. | 1.5 | E2EC-C1R5D□ | ||||||||||
8dia. | 3 | E2EC-C3D□ | ||||||||||
M12 | 4 | E2EC-X4D□ |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit : mm) |
Features | Specifications | Model | |
---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
|||||||
E2CY | Separate Amplifier for Aluminum Detection |
Shielded |
M5 | 1.5 | • Detects non-ferrous metals such as aluminum and copper • Comes with teaching and sensitivity margin displays |
DC (3-Wire) |
DC 3-Wire : NPN NO/NC (Selectable) |
E2CY-X1R5A +E2CY-T11 |
5.4dia. | E2CY-X1R5A-1 +E2CY-T11 |
|||||||
8dia. | 2 | E2CY-C2A(F) +E2CY-T11 |
||||||
12×25 ×4.5 |
3 | E2CY-V3A +E2CY-T11 |
||||||
E2C-H | Heat-Resistant Type |
Shielded |
M8 | 1.5 | • Standard type • Pre-wired connector type • Metal case with Fluororesin coating |
DC (2-Wire) |
NPN NO |
E2C-X1R5AH +E2C-JC4CH |
M12 | 2 | E2C-X2AH +E2C-JC4DH |
||||||
M18 | 5 | E2C-X5AH +E2C-JC4EH |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Pre-wired Type |
Series | Appearance | Shielded/ Unshielded |
Size | Detecting Distance (Unit:mm) |
Features | Specifications | Model | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
Connector Type |
Different Frequency Type |
Robotics Cable Type |
||||||||
NPN etc. | PNP | |||||||||||
E2E | Long Distance Type |
Unshielded |
34dia. | 3 to 25 | • Adjustable Sensitivity | DC (3-Wire) or AC |
DC Type : NPN NO or NC AC Type : NO or NC |
- | - | - | - | E2K-C25M@ |
3 to 20 | DC (3-Wire) AC/DC Selectable (2-Wire) |
E2K-C20M@ | ||||||||||
E2K-X | Generalpurpose Type |
Unshielded |
M12 | 4 | - | DC (3-Wire) or AC |
DC Type : NPN NO or NC AC Type : NO or NC |
- | - | - | - | E2K-X4M@ |
M18 | 8 | E2K-X8M@ | ||||||||||
M30 | 15 | E2K-X15M@ | ||||||||||
E2K-F | Flat Type |
Unshielded |
50×20 ×10.1 |
10 | • Thickness : 10mm | DC (3-Wire) |
NPN NO or NC |
- | - | - | - | E2K-F10MC@ |
4 to 10 | E2K-F10MC@-A | |||||||||||
E2J | Flat, Separate Amplifier Type |
Unshielded |
20×30 ×5.5 |
4 to 10 | • Must be used together with E2J-JC4A Amplifier Unit |
DC (3-Wire) |
NPN NO or NC (Selectable) |
- | ○ | - | ○ | E2J-W10MA +E2J-JC4A |
30×40 ×5.5 |
8 to 20 | E2J-W20MA +E2J-JC4A |
||||||||||
E2E | Chemical Resistant Type |
Unshielded |
M18 | 6 to 10 | • Fluororesin Case • Adjustable Sensitivity Type (Except for Cable) |
DC (3-Wire) or AC |
NPN NO |
- | - | - | - | E2KQ-X10ME1 |
Note:The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Series | Appearance | Applicable Pipe Diameter |
Features | Specifications | Model | |
---|---|---|---|---|---|---|
Power Supply |
Output Configuration |
|||||
E2K-L | 8 to 11dia. | • Supports a wide range of pipe diameters • Built-in amplifier, space-saving |
DC (2-Wire) |
NPN NO |
E2K-L13MC1 | |
12 to 26dia. | E2K-L26MC1 |
Note:The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.
Series | Appearance | Detecting Distance (Unit:mm) |
Specifications | Model | |
---|---|---|---|---|---|
Power Supply |
Output Configuration |
||||
TL-M | Micro Switch Type |
2 | DC (3-Wire) |
NO or NC | TL-M2ME@ |
AC (2-Wire) |
NO | TL-M2MY1 | |||
5 | DC (3-Wire) |
NO or NC | TL-M5ME@ | ||
AC (2-Wire) |
NO | TL-M5MY1 | |||
TL-L | Cylindrical Type |
100 | DC (3-Wire) |
Current Output Type NO |
TL-L100-7 |
Series | Type | Model |
---|---|---|
GLS | Set | GLS-1 |
Switch Unit | GLS-S1 | |
Magnet Unit | GLS-M1 |
Note: The table above contains only general specifications. Make sure that you read through the corresponding page for the detailed specifications and precautions before using.